What is the difference between N1 interface and N2 interface in 5G? - mobile

In every 5G diagram, they have the N1 interface directly connected to the UE. Is it really a direct connection? or is it still going through the radio? If so what is the difference from N2?

RAN uses N2 (control plane) and N3 (user plane) to interface to the core and transparent N1 interface to the user devices. N1 is a transparent interface from 5G-UE to AMF of core(via NG-RAN).
N1 interface is used by UE for transmitting non radio signalling between UE and AMF (something like NAS) which includes information related to connection, mobility and session related messages to the AMF which handles cases related to connection, mobility messages, but forwards session management info to SMF.
N2 interface supports control plane signalling between RAN and 5G core covering scenarios related to UE context management, PDU session/resource management procedures. N2 uses SCTP (NGAP) between 5GCN and access network.

N1 is for the Non-Access Stratum (NAS) protocol between the core network and the handset, N2 is a network interface between the core network and the base station.

N1 : Between UE and AMF (The N1 interface is used by the UE for non-radio signaling mainly NAS layer signaling.)
N2: Between gNB and AMF
N1/N2 : between gNB and AMF (supporting UE and non-UE related services.)
and 3) both are valid between gNB and AMF.

The N1 is a direct connection between the UE and the 5G core network (AMF). As any connection is transmitted over the air, and it´s therefore a radio connection at whichever frequency. The difference here is that the NAS messages are transmitted "transparently" through the radio protocol stack within the gNodeB (without being processed through the L1-L3 layer stack, where PDUs get headers/padding added), but it is still going "through" the radio, there is no real (as in physical) connection between UEs and 5G core (actually the 5G core can be located many miles away from the gNodeB). Hope it helps.

Related

What is the meaning of 'sender=:1.478' in dbus-monitor?

Nowadays I am analyzing d-bus in Chromium OS (Chrome OS).
I captured meaningful d-bus method calls (below), when I press ''guest' button on login UI.
my-cros # dbus-monitor --system "path=/org/chromium/Session Manager"
method call time=1632311881.319994 sender=: 1.478 -> destination=org.chromium. SessionManager serial=378 path=/org/chromium/Session Manager; interface=org.chromium.SessionManager Interface: member=LoadShil1Profile
string "$guest"
method call time=1632311881.319417 sender:1.478 -> destination=org. chromium. Session Manager serial=371 path=/org/chromium/SessionManager; interface=org.chromium.SessionManager Interface: member-SetFeatureFlagsFor User string "$guest"
array [
]
array [
]
I know that org.chromium.SessionManager is the one who starts guest/google-id session.
Btw what is the meaning of 'sender=:1.478'?
And how to track the sender process?
Thank you in advance.
Firstly, you might find it easier to visualise what’s going on by using Bustle instead of dbus-monitor.
sender=:1.478 means the message you’re looking at was sent by the connection with unique ID :1.478 on the bus. Each connection to the bus (roughly, each process, although a process can actually have more than one connection) has a unique ID, and some connections also have ‘well-known’ IDs which look like reverse-DNS names. For example org.chromium.SessionManager.
You can track the sender process by looking for the same unique ID appearing as the sender or destination of other messages. Using Bustle will make this easier, as it can group and filter messages by sender/destination.

get_multiple_points volttron RPC call

Any chance I could get a tip for proper way to build an agent that could do read multiple points from multiple devices on a BACnet system? I am viewing the actuator agent code trying learn how to make the proper rpc call.
So going through the agent development procedure with the agent creation wizard.
In the init I have this just hard coded at the moment:
def __init__(self, **kwargs):
super(Setteroccvav, self).__init__(**kwargs)
_log.debug("vip_identity: " + self.core.identity)
self.default_config = {}
self.agent_id = "dr_event_setpoint_adj_agent"
self.topic = "slipstream_internal/slipstream_hq/"
self.jci_zonetemp_string = "/ZN-T"
So the BACnet system in the building has JCI VAV boxes all with the same zone temperature sensor point self.jci_zonetemp_string and self.topic is how I pulled them into volttron/config store through BACnet discovery processes.
In my actuate point function (copied from CSV driver example) am I at all close for how to make the rpc call named reads using the get_multiple_points? Hoping to scrape the zone temperature sensor readings on BACnet device ID's 6,7,8,9,10 which are all the same VAV box controller with the same points/BAS program running.
def actuate_point(self):
"""
Request that the Actuator set a point on the CSV device
"""
# Create a start and end timestep to serve as the times we reserve to communicate with the CSV Device
_now = get_aware_utc_now()
str_now = format_timestamp(_now)
_end = _now + td(seconds=10)
str_end = format_timestamp(_end)
# Wrap the timestamps and device topic (used by the Actuator to identify the device) into an actuator request
schedule_request = [[self.ahu_topic, str_now, str_end]]
# Use a remote procedure call to ask the actuator to schedule us some time on the device
result = self.vip.rpc.call(
'platform.actuator', 'request_new_schedule', self.agent_id, 'my_test', 'HIGH', schedule_request).get(
timeout=4)
_log.info(f'*** [INFO] *** - SCHEDULED TIME ON ACTUATOR From "actuate_point" method sucess')
reads = publish_agent.vip.rpc.call(
'platform.actuator',
'get_multiple_points',
self.agent_id,
[(('self.topic'+'6', self.jci_zonetemp_string)),
(('self.topic'+'7', self.jci_zonetemp_string)),
(('self.topic'+'8', self.jci_zonetemp_string)),
(('self.topic'+'9', self.jci_zonetemp_string)),
(('self.topic'+'10', self.jci_zonetemp_string))]).get(timeout=10)
Any tips before I break something on the live system greatly appreciated :)
The basic form of an RPC call to the actuator is as follows:
# use the agent's VIP connection to make an RPC call to the actuator agent
result = self.vip.rpc.call('platform.actuator', <RPC exported function>, <args>).get(timeout=<seconds>)
Because we're working with devices, we need to know which devices we're interested in, and what their topics are. We also need to know which points on the devices that we're interested in.
device_map = {
'device1': '201201',
'device2': '201202',
'device3': '201203',
'device4': '201204',
}
building_topic = 'campus/building'
all_device_points = ['point1', 'point2', 'point3']
Getting points with the actuator requires a list of point topics, or device/point topic pairs.
# we only need one of the following:
point topics = []
for device in device_map.values():
for point in all_device_points:
point_topics.append('/'.join([building_topic, device, point]))
device_point_pairs = []
for device in device_map.values():
for point in all_device_points:
device_point_pairs.append(('/'.join([building_topic, device]),point,))
Now we send our RPC request to the actuator:
# can use instead device_point_pairs
point_results = self.vip.rpc.call('platform.actuator', 'get_multiple_points', point_topics).get(timeout=3)
maybe it's just my interpretation of your question, but it seems a little open-ended - so I shall respond in a similar vein - general (& I'll try to keep it short).
First, you need the list of info for targeting each device in-turn; i.e. it might consist of just a IP(v4) address (for the physical device) & the (logical) device's BOIN (BACnet Object Instance Number) - or if the request is been routed/forwarded on by/via a BACnet router/BACnet gateway then maybe also the DNET # & the DADR too.
Then you probably want - for each device/one at a time, to retrieve the first/0-element value of the device's Object-List property - in order to get the number of objects it contains, to allow you to know how many objects are available (including the logical device/device-type object) - that you need to retrieve from it/iterate over; NOTE: in the real world, as much as it's common for the device-type object to be the first one in the list, there's no guarantee it will always be the case.
As much as the BACnet standard started allowing for the retrieval of the Property-List (property) from each & every object, most equipment don't as-yet support it, so you might need your own idea of what properties (/at least the ones of interest to you) that each different object-type supports; probably at the very-very least know which ones/object-types support the Present-Value property & which ones don't.
One ideal would be to have the following mocked facets - as fakes for testing purposes instead of testing against a live/important device (- or at least consider testing against a noddy BACnet enabled Raspberry PI or the harware-based like):
a mock for your BACnet service
a mock for the BACnet communication stack
a mock for your device as a whole (- if you can't write your own one, then maybe even start with the YABE 'Room Control Simulator' as a starting point)
Hope this helps (in some way).

Windows: Disabling CPU idle C-states from kernel-mode driver

I'm writing an audio device driver which needs to process device interrupts in real-time. When the CPU enters C3 state, interrupts are delayed, causing problems to the driver. Is there a way for the driver to tell the OS not to enter idle C-states?
What I've found is that idle C-states can be disabled from user-space:
const DWORD DISABLED = 1;
const DWORD ENABLED = 0;
GUID *scheme;
PowerGetActiveScheme(NULL, &scheme);
PowerWriteACValueIndex(NULL, scheme, &GUID_PROCESSOR_SETTINGS_SUBGROUP, &GUID_PROCESSOR_IDLE_DISABLE, DISABLED);
PowerSetActiveScheme(NULL, scheme);
However, it is a global setting, which can be overwritten by the user or another application (e.g. when the user changes the Power Plan).
What I need is something like PoRegisterSystemState, but not for S- and P-states, but for C-states. (ref: https://learn.microsoft.com/en-us/windows-hardware/drivers/kernel/preventing-system-power-state-changes)
Is there any way to achieve this?
=====
It turns out there isn't a supported way to disable idle C-states from kernel space, and there isn't a service in user space to provide common API to do this.
The way to control C-states is from "Processor Power Management" in "Change advanced power settings" dialog, through registry, or via C API PowerWriteACValueIndex / PowerWriteDCValueIndex.
The original problem was delayed interrupts in all but C1 idle state, so I needed to disable both C2, C3 and deeper idle states. The problem with disabling all idle C-states, including C1 (as shown in the example code PowerWriteACValueIndex(NULL, scheme, &GUID_PROCESSOR_SETTINGS_SUBGROUP, &GUID_PROCESSOR_IDLE_DISABLE, DISABLED)) is that the CPU usage is reported as 100%, and some applications (DAWs) get confused.
The solution for my problem is to disable all but C1 idle state, which can be done by setting the following values in the Processor Power Management:
- Processor idle threshold scaling -> Disable scaling;
- Processor idle promote threshold -> 100%;
- Processor idle demote threshold -> 100%.
Perhaps I'll create a service that does just that, that will use the PowerWriteACValueIndex / PowerWriteDCValueIndex API.

Gatling repeat with connection re-use

With Gatling 2, is it possible to repeat with connection re-use? How?
I have the below code, but it appears to open new connection every time. I want to maintain x connections for some time.
val httpProtocol = http
.baseURL("http://mysrv.pvt")
.inferHtmlResources()
val uri1 = "http://mysrv.pvt"
val scn = scenario("Simulation").repeat(50){
pause(2 seconds,20 seconds).
exec(http("request_0")
.get("/s1/serve.html")
)
}
setUp(scn.inject(
atOnceUsers(20000)
).protocols(httpProtocol))
First, your question is not accurate enough.
By default, Gatling has one connection pool per virtual user, so each of them do re-use connections between sequential requests, and can have more than one concurrent connection when dealing with resource fetching, which you do as you enabled inferHtmlResources. This way, virtual users behave as independent browsers.
You can change this behavior and share a common connection pool, see doc. However, you have to make sure this makes sense in your case. Your workload profile will be very different, the toll on the TCP stack on both the client/Gatling and the server/your app will be way less, so make sure that's how your application is being used in production.

Refresh multicast group membership

I have several embedded machines listening and streaming rtp audio data to a multicast group. They are connected to a smart managed switch (Netgear GS108Ev2) which does basic igmp snooping and multicast filtering on its ports, so that the rest of my (W)LAN doesn't get flooded.
At start everything works fine for about 500-520 seconds. After that, they don't receive any more data until they leave and join the group again. I guess the switch is "forgetting" about the join after a timeout.
Is there any way to refresh the group membership, i.e. letting the switch know, that there ist still someone listening, without losing packets?
System info:
Arch: blackfin
# cat /proc/version
Linux version 2.6.28.10-ADI-2009R1-uCBF54x-EMM
(gcc version 4.3.3 (ADI) ) #158 PREEMPT Tue Jun 5 20:05:42 CEST 2012
This is the way multicast / the IGMP protocol works. A client has to join the group periodically by sending a Membership Report or it will be assumed that he has left the group after some short timeout. However, those reports are usually sent only when receiving a Membership Query from the local multicast router. Either your clients don't receive the query or don't respond with a report.
Try to use a tool like wireshark in order to see which IGMP packets are sent through your network.
You need an IGMP querier to send the Membership Queries, as was already explained by scai.
If you can't configure your router to do that, you can use one of your computers. Seeing how running a full multicast routing daemon would be overkill (and I've never done that), I suggest you try to abuse igmpproxy.
First create a dummy upstream interface (this is not persistent!):
ip tap add dev tap6 mode tap
Write igmpproxy.conf:
# Dummy upstream interface.
phyint tap6 upstream ratelimit 0 threshold 1
# Local interface.
phyint eth0 downstream ratelimit 0 threshold 1
# Explicitly disable any other interfaces (yes, it sucks).
phyint NAME disabled
...
Finally start igmpproxy (as root):
igmpproxy -v /path/to/igmpproxy.conf
If your embedded devices are running linux, you need to turn off the reverse packet filter on them or they won't respond to group membership queries. In that case the upstream switch will assume there is no-one listening to that multicast and switch it off.
I had same problem, multicast on wifi was lost after 260 seconds, I solved it with my application by adding AddSourceMembership on socket.
private void StartListner(IPAddress sourceIp, IPAddress multicastGroupIp, IPAddress localIp, int port)
{
try
{
Socket socket = new Socket(AddressFamily.InterNetwork, SocketType.Dgram, ProtocolType.Udp);
IPEndPoint localEndpoint = new IPEndPoint(localIp, port);
socket.Bind(localEndpoint);
byte[] membershipAddresses = new byte[12]; // 3 IPs * 4 bytes (IPv4)
Buffer.BlockCopy(multicastGroupIp.GetAddressBytes(), 0, membershipAddresses, 0, 4);
Buffer.BlockCopy(sourceIp.GetAddressBytes(), 0, membershipAddresses, 4, 4);
Buffer.BlockCopy(localIp.GetAddressBytes(), 0, membershipAddresses, 8, 4);
socket.SetSocketOption(SocketOptionLevel.IP, SocketOptionName.AddSourceMembership, membershipAddresses);
try
{
byte[] b = new byte[1024 * 2];
int length = socket.Receive(b);
}
catch { }
}
catch (Exception ex)
{
logger.Error("Exception: " + ex);
}
}